In a 100-patient retrospective series, a five-zone "Dou-gong" technique injected hyaluronic acid above periosteum or perichondrium to reinforce nasal ligament support, with no vascular occlusion or material displacement. Shifting injection rhinoplasty from volume stacking to ligament support is conceptually right, but a single-arm Level IV series without objective measurement proves feasibility only.
Among 1,153 consecutive ePTFE rhinoplasties, overall infection incidence was about 1.6%, and more than half of infections presented beyond six months, including cases after one year. Late-onset infection is common rather than exceptional, so follow-up must extend past the first year and modifiable risks such as smoking and revision belong in preoperative planning.
Acta Otorrinolaringologica Española · PMID 42914090 · doi
事实|综述:鼻皮肤坏死主因是翻修、吸烟、皮瓣过度打薄;早期硝酸甘油、高压氧、己酮可可碱可救。
点评|真正该背的是风险清单和早期识别;等皮肤发黑再上药,多半只剩清创。
A review identified revision surgery, smoking and aggressive flap thinning as the main risk factors for nasal skin necrosis, with early topical nitroglycerin, hyperbaric oxygen and pentoxifylline suggested for salvage. The protocol's value lies in preoperative risk stratification and early recognition; salvage drugs started after the skin turns black rarely change the outcome.
Plastic and Reconstructive Surgery · PMID 42873118 · doi
事实|561例拉皮:内部止血网加渐进张力缝合,不放引流不加压,血肿清创0例,对照5.9%。
点评|降到0靠的是消灭死腔不是压迫包扎;但面神经暂时麻痹10.4%,签字前得说。
In a 561-patient comparative series, an internal hemostatic network with progressive tension sutures and no drains or compression produced zero hematomas requiring evacuation versus 5.9% in controls, with transient marginal mandibular weakness in 10.4%. Eliminating dead space beats external pressure for hematoma prevention, but a 10.4% transient nerve weakness rate is the price and belongs in consent.
Of 198 women with Grade I ptosis selected for dual-plane augmentation alone, 1.0% were revised for superior malposition, one later chose mastopexy and none developed contracture. Grade I ptosis is not an automatic mastopexy indication; glandular volume, tissue quality and expectation alignment decide whether extra scars are justified.
In 590 consecutive patients screened with high-resolution ultrasound, implant flipping was found in 12.7%, independently associated with larger volume, prepectoral placement and lack of soft tissue support. One in eight implants is flipped, often silently; in-office ultrasound turns a vague complaint into an objective finding and belongs in routine follow-up.
还没有批注